Provista Chart

PROVISTA Copolymer

Preliminary Data Sheet

Provista copolymer is a resin specifically developed for extrusion into profiles where aesthetics like high clarity and gloss, coupled with design flexibility drive demand.

Property (a)Test Method (b)Value, Units (c)
  General Properties
DensityD 7921.27 g/cm3
  Mechanical Properties
Tensile Stress @ YieldD 63850 MPa (7300 psi)
Tensile Stress @ BreakD 63829 MPa (4200 psi)
Elongation @ YieldD 6384%
Elongation @ BreakD 638109%
Flexural ModulusD 7902200 MPa (3.2 x 105 psi)
Flexural StrengthD 79072 MPa (10400 psi)
Rockwell Hardness, R ScaleD 785106
Izod Impact Strength, Notchedd
        @ 23°C (73°F)D 25694 (9C/1NB) J/m(1.8 (9C/1NB) ft·lbf/in.)
        @ -40°C (-40°F)D 25652C J/m (1.0C ft·lbf/in.)
Impact Strength, Unnotchede
        @ 23°C (73°F)D 4812NB
        @ -40°C (-40°F)D 4812NB
Impact Resistance (Puncture), Energy @ Max. Loadf
        @ 23°C (73°F)D 376333 J (24 ft·lbf)
        @ 0°C (32°F)D 376337 J (27 ft·lbf)
        @ -40°C (-40°F)D 376341 J (30 ft·lbf)
  Thermal Properties
Deflection Temperature
        @ 0.455 MPa (66 psi)D 64867°C (153°F)
        @ 1.82 MPa (264 psi)D 64862°C (144°F)
Vicat Softening Temperature @ 1 kg loadD 152579°C (174°F)
  Optical Properties
HazeD 10030.6%
Regular TransmittanceD 100388%
Total TransmittanceD 100390%
Gloss @ 60°D 2457171
Color, b* CIELAB, Illuminant D6500, 10° ObserverD 22440.61

Unless noted otherwise, all tests are run at 23oC (73oF) and 50% relative humidity.
Unless noted otherwise, the test method is ASTM.
Units are in SI or US customary units.
d Testing conducted using 10 standard flex bars with 20 mil notch; C = complete break; NB = nonbreak.
e Nonbreak as defined by ASTM D 4812.
f Testing conducted using 10 standard 4″ x 4″ x0.125″ thick injection molded plaques; 100% ductile break.

Comments

Properties reported here are based on limited testing. Eastman makes no representation that the material in any particular shipment will conform exactly to the values given.

Neither Eastman Chemical Company nor its marketing affiliates shall be responsible for the use of this information, or of any product, method, or apparatus mentioned, and you must make your own determination of its suitability and completeness for your own use, for the protection of the environment, and for the health and safety of your employees and purchasers of your products. No warranty is made of the merchantability of fitness of any product, and nothing herein waives any of the Seller’s conditions of sale.